Delay Timer Relay Module 1 Channel 5V

SKU: 2816756

450.00৳ 

20 People watching this product now!
জিজ্ঞাসা

Description

Description

Delay Timer Relay Module 1 Channel 5V

1 way relay module, time delay power cut off, trigger delay cycle timer circuit switch.
0.1 second (min) ~999 min (max) continuous tunable
This product is simple and easy to use, powerful, but please buyers in detail to see the operation instructions of this product, very practical products.
Module highlights:
1. wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use.
2. the interface is clear and simple, powerful, easy to understand, almost meet all your needs.
3., there is one button emergency stop function (STOP key), with reverse connection protection, reverse connection without burning.
4. increase the sleep mode and enable the operator to turn off the display automatically after 5 minutes without any operation.
5., you can set different parameters of OP, CL and LOP, which are independent of each other.
6. all set parameters automatically save the power.
Work model:
After the P1: signal is triggered, the relay will lead to OP time and then disconnect; in OP time, the following operations are performed.
P1.1: signal re – trigger invalid
P1.2: the signal triggers the time again
P1.3: the signal is triggered again, the relay is disconnected, and the timer is stopped.
P-2: to trigger the signal, the relay disconnects the CL time, the relay conducts OP time, and after the timer is completed, the relay is disconnected.
P3.1: after the trigger signal is triggered, the relay opens the time of OP, the relay disconnects the CL time, and then circulate the above action, the relay is given again the signal, the relay is disconnected and the timing is stopped; the cycle times (LOP) can be set;
P3.2: after power on, there is no need to trigger the signal, the relay can lead OP time, the relay disconnects CL time, circulate the above actions, and the number of cycles (LOP) can be set.
P-4: if the signal has a trigger signal, the timing is zero, the relay is kept open; when the signal is disappearing, the relay is broken after the time of time OP; during the time of time, the signal is repeated and the time is zero;
Product parameters:
1: working voltage: 6–30V supports micro USB 5.0V power supply.
2: trigger signal source: high level triggering (3.0V – 24V) signal does not improve the system’s anti-jamming capability with the system.
3: output capability: equipment that can control DC 30V 5A or less than 220v5A.
4: static current: 20mA working current: 50mA
5: service life: greater than 100 thousand times; working temperature: -40 – 85 C; size: 6.2*3.8*1.7cm
6: with optocoupler isolation, enhance anti-interference ability, industrial grade circuit boards, set parameters after power failure forever.
Memory.
Special attention: relay output is passive contact, uncharged output, to control the role of a circuit on and off.
Time range
0.1 second (min) ~999 min (max) continuous tunable
How to choose the time range:
After setting the parameter values in the mode selection interface, select the time range by short pressing the STOP key.
XXX. decimal point in bit, time range: 1 second ~999 sec.
XX.X decimal point in ten places, time range: 0.1 seconds ~99.9 seconds.
X.X.X. the decimal point is bright. The time range is 1 minutes ~999 minutes.
For example, if you want to set OP to 3.2 seconds, move the decimal point to ten bits, and the digital tube displays 3.2.
Parameter Description: OP lead time, CL disconnection time, LOP cycle number (1 to 999 times, “—” represents infinite cycle).
These parameters are independent of each other, but each pattern shares these parameters, for example, in the P1.1 setting the pass time OP is 5 seconds, the user wants to switch to the P1.2 mode, then the OP will be 5 seconds when the corresponding parameters are set into the P1.2;
At the main interface (display 000), short press SET button will display OP (CL, LOP) and the corresponding time XXX;
If there is only OP (for example, mode P1.1, P1.2, P1.3) in the pattern, then the short SET key will only show OP and the corresponding time.
If there are OP, CL and LOP (for example, mode P3.1, P3.2) in the pattern, the short pressing of SET key will display OP and corresponding time, CL and corresponding time, LOP and corresponding times;
After setting up the mode, you can easily view the parameters set in the current mode by short pressing the SET key in the main interface, which is very convenient.
How to set parameters
1. first, determine the working mode of the relay.
2. according to the working mode of the relay, when the main interface is on the main interface, it will flicker the current working mode (the default P1.1 mode), and then enter the main interface, and “long press SET key” into the mode selection interface after 2 seconds, and select the mode to set by short press UP and DOWN keys (P1.1~P-4).
3. after selecting the mode to set up (for example, P3.2) set the corresponding parameters by the SET key, the parameters to be set will flicker (OP conduction time, CL break time, LOP cyc

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Delay Timer Relay Module 1 Channel 5V”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5